*Welding current check monitor exclusively used for single phase AC welding machine.
*Measure effective value and welding cycle correctly.
*Monitor upper and lower limits are set up with 15c onditions.
*Managing spot welding quantity with preset counter.
*Buzzer alarms for welding defects etc. by monitoring.
*Telecommunication function RS232C and RS485 are installed,which facilitates the adoption of computer management.
MODEL | UEM-028 | ||||
MEASURE | CURRENT | MEASURE RANGE | 0.40~9.99KA/3.0~99.9KA | ||
MEASURE VALUE | Average effect value | ||||
MEASURE INDICATE | 3-digit digital display (7 segment LED) | ||||
MEASURE RANGE SETTING | START | AC | 00~99 CYCLE (15 CONDITIONS) | ||
FINISH | 00~99 CYCLE (15 CONDITIONS) | ||||
MEASUREMENT ACCURACY | Full Range±2%±2d | ||||
DETECTION MEANS | Toroidal Coil | ||||
TIME | PULSE WIDTH OF POWER CYCLE | MEASURE RANGE | The max measuring time is 99.5 cycles | ||
MEASURE INDICATE | 3-digit digital display(7 segment LED) | ||||
DETECTION MEANS | Toroidal Coil | ||||
MONITOR | WELD CURRENT | The upper and lower limit specification can be set up to 15 conditions, the setting range is 0.00~9.99KA/00.0~99.9KA | |||
WELD TIME(CYCLE) | The upper and lower limit specification can be set up to 15 conditions, the setting range is 0.00~99.5CYC | ||||
NO CURRENT DETECTION | When the current value of welding is below the sensitivity or below 2% of full scale, it means NO ENERGIZING. Output a relay signal. | ||||
JUDGEMENT INDICATION | The lamps of the normal value, upper specification value, lower specification value and no-energizing light in the corresponding cases. | ||||
JUDGEMENT OUTPUT | 「NOR」is 0.1s.「LOW,HIGH=NO GOOD」and「NO CURR」is ON for long time until reset .「LOW,HIGH」makes alarm for 1.5s or a long time with AC bugger . | ||||
IMPULSE SETTING | (setting the number of pulsation welding) |
COUNTER | 5-digit |
COUNTER OUTPUT | The DC buzzer will continue when it reaches the preset value, use the reset-button to stop the buzzer. |
COMMUNICATION OUTPUT | The measured current value, the time of energizing, the result of judgment, the counter value and schedule data can communicate with RS-232C/RS-485 |
POWER SOURCE | Single-phase AC85~240V ±10%(50/60Hz)switching automatically |
CASE SIZE(mm) | 210(D)×87(W)×192(H) |
WEIGHT | 2kg |
SURROUNDING TEMPERATURE | 0~45℃ |
CONSUMPTION POWER | 15VA |